Capacity and escape route calculator

How many people may be on your site or in your hall? The question has three answers, not one: the floor area sets one limit, the width of the exits sets a second, and the permit may set a third. The smallest one applies — and in practice it is rarely the one you thought of first.

Written for people organising LARPs, conventions, medieval markets, theatre and club events who want to know what they are talking about before they file with the licensing authority. The calculator shows all three limits together and tells you how much exit width is missing when the escape routes are the bottleneck.

The number this produces is the starting point for everything else — it opens the Safety concept assistant and it decides how much medical cover you need: Medical services calculator.

Your figures

Only the area visitors actually use — excluding stage, technical areas, storage and sanitary facilities.
Counted against the escape routes, not against the area.
Exits and their clear width

Clear width in metres — what is actually free, not the door's nominal size.

Does your permit name a maximum? Enter it here.

This result does not hold

  • Without a floor area there is no capacity to calculate. Enter the area visitors actually use.
  • Choose how the space is used. Standing, seated at tables or seated in rows halves or doubles the permissible number.
  • Choose whether the area is inside a building or in the open. Escape route widths are measured differently for each.
  • No exit is entered. Without an escape route there is no permissible visitor number.

Maximum number of visitors

0 persons

The floor area is the binding limit.

  • 0 persons by floor area
  • 0 persons by escape routes
  • 0 persons — Total people on site (including crew)
  • Creditable exit width: 0.00 m
  • Required for this number of people: 0.00 m

Without an exit of at least 1.20 m clear width there is no permissible visitor number.

How this is calculated

Capacity by area follows MVStättVO § 1 Abs. 2: one visitor per square metre for seating at tables and for exhibition rooms, two per square metre for row seating and standing room.

Escape route capacity follows § 7 Abs. 4: every 1.20 m of clear width carries 200 people out of a building and 600 off an open-air site, because outdoors there is no smoke to outrun. Width is measured in units of 0.60 m, the width of one person-stream. A 1.50 m exit therefore counts as 1.20 m, and anything under 1.20 m is not an escape route at all.

Crew count towards the escape routes, because everyone has to get out. They do not count towards the area limit, which measures visitor places. So the calculator subtracts crew from the escape route capacity and not from the area capacity.

  • MVStättVO § 1 Abs. 2 — determining visitor numbers
  • MVStättVO § 7 Abs. 4 — dimensioning escape route width
  • MVStättVO § 43 Abs. 2 — safety concept from 5,000 visitors

Every figure with its source and review date is in the metrics register — including when it was last checked against the regulation.